[1] BEYER C, JENETT H, KLOCKOW D. Influence of reactive SF x gases on electrode surfaces after electrical discharges under SF 6 atmosphere[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2000, 7(2): 234-240. [2] JAMES D R, SAUERS I, GRIFLIN G D, et al . Investigation of S 2 F 10 production and mitigation in compressed SF 6 -insulated power systems [J]. IEEE Transactions on Electrical Insulation, 1993, 9(3): 29-40. [3] 狄谦,刘之方,李国富. 550 kV SF 6 气体绝缘组合电器套管研制[J]. 中国电力,2010,43(10):16-19. DI Qian, LIU Zhi-fang, LI Guo-fu. Development of 550 kV SF 6 gas-insulated swltchgear(GIS)’s bushings[J]. Electric Power,2010, 43(10): 16-19. [4] 孟玉婵,朱芳菲. 电气设备用六氟化硫的检测与监督[M]. 北京:中国电力出版社,2008:113-118,134-137. [5] 唐嘉. 电气绝缘设备故障时气体特征分解物的检测及应用[J]. 中国电力,2011,44(5):31-33. TANG Jia. Detection of gas decomposition products of SF 6 gas- insulated electric equipment under faults and its applications [J].Electric Power, 2011, 44(5): 31-33. [6] 颜湘莲,王承玉,季严松,等. 开关设备中SF 6 气体分解产物检测的应用[J]. 电网技术,2010,34(9):160-165. YAN Xiang-lian, WANG Cheng-yu, JI Yan-song, et al . Application of decomposition products detection of SF 6 in switchgears [J]. Power System Technology, 2010, 34(9): 160-165. [7] TOMINAGA S, KUWAHARA H, HIROOKA K, et al . SF 6 gas analysis technique and its application for evaluation ofinternal conditions in SF 6 gas equipment[J]. IEEE Transactions on Power Apparatus and Systems, 1981, 100(9): 4196-4206. [8] 胡红红,钟建灵,郑亚君. 运行中SF 6 全封闭组合电器的故障检测[J]. 中国电力,2010,43(12):19-22. HU Hong-hong, ZHONG Jian-ling, ZHENG Ya-jun. Online fault detection for SF 6 gas-insulated metal-enclosed switchgears[J].Electric Power, 2010, 43(12): 19-22. [9] 刘有为,吴立远,弓艳朋. GIS 设备气体分解物及其影响因素研究[J]. 电网技术,2009,33(5):58-61. LIU You-wei, WU Li-yuan, GONG Yan-peng. Investigation on SF 6 decomposition products in GIS and affecting factors [J]. Power System Technology, 2009, 33(5): 58-61. [10] 袁亮. 高压电器中SF 6 气体分解物的检测与研究[D]. 长春:长春理工大学,2009. [11] 唐炬,陈长杰,张晓星,等. 微氧对SF 6 局部放电分解特征组份的影响[J]. 高电压技术,2011,37(1):8-13. TANG Ju, CHEN Chang-jie, ZHANG Xiao-xing, et al . Influence of trace-level O 2 on SF 6 decomposition characteristics under partial discharge[J]. High Voltage Engineering, 2011, 37(1): 8-13. [12] 袁平,付汉江,袁先亮. 便携式色谱仪在六氟化硫电气设备故障检测中的应用研究[J]. 华中电力,2010,23(6):48-53. YUAN Ping, FU Han-jiang, YUAN Xian-liang. Application of portable chromatograph in SF 6 electrical devices fault detecting[J]. Central China Electric Power, 2010, 23(6): 48-53. [13] 唐炬,朱黎明,刘 帆,等. 应用光声技术的SF 6 分解组分检测装置研制[J]. 高电压技术,2011,37(6):1313-1320. TANG Ju, ZHU Li-ming, LIU Fan, et al . Development of SF 6 decomposition components detection device using acoustic technology [J]. High Voltage Engineering, 2011, 37(6): 1313-1320. [14] IEC 60480-2004 Guidelines for the checking and treatment of sulfur hexafluoride(SF 6 ) taken from electrical equipment and specification for its re-use [S]. [15] 国家电网公司生变电[2010]11号—2010:电力设备带电检测技术规范(试行)[S]. [16] Q/CSG 114002—2011 电力设备预防性试验规程[S]. [17] GB/T 12022—2006 工业六氟化硫[S]. [18] GB 8905—1996 六氟化硫电气设备中气体管理和检测导则[S]. |