Electric Power ›› 2018, Vol. 51 ›› Issue (12): 124-131.DOI: 10.11930/j.issn.1004-9649.201805001

Previous Articles     Next Articles

Application of Data Reconciliation in Steam Turbine Performance Monitoring

HU Jiangen1, GU Zhenghao1, BAO Jinsong1, ZHU Meifang1, ZHANG Bao2   

  1. 1. State Grid Zhejiang Electric Power Research Institute, Hangzhou 310014, China;
    2. HangZhou E. Energy Technology Co., Ltd., Hangzhou 310014, China
  • Received:2018-05-02 Revised:2018-06-06 Online:2018-12-05 Published:2018-12-13

Abstract: In the steam turbine thermodynamic cycle, the measuring system has provided redundant measuring points. Generally, the main water flow, the main condensate flow and the feed water pump inlet flow are chosen as the mainstream in the on-site performance calculation. In this paper, by using the data reconciliation method, the redundant flow measurement point information is taken to perform data reconciliation calculation regarding the performance data of a real power plant. Then the uncertainty changes of the calculation result are analyzed. The result shows that the data reconciliation can effectively reduce the uncertainty of the calculation result.

Key words: steam turbine, thermodynamic performance, data reconciliation, uncertainty, redundancy, heat rate

CLC Number: