300 MW机组引、增压风机二合一改造后动调风机振动原因分析及解决方案

薛翔1, 邱勇1, 马翔2, 郑金2, 李凯伦2, 张振民1   

  1. 1. 中国电建集团透平科技有限公司, 四川 成都 610054;
    2. 西安热工研究院有限公司, 陕西 西安 710032
  • 收稿日期:2018-09-30 修回日期:2018-12-29 出版日期:2019-06-05 发布日期:2019-07-02
  • 作者简介:薛翔(1970-),男,工程师,从事电站风机工艺设计和销售工作,E-mail:cdxuex@126.com 郑金(1981-),男,高级工程师,从事电站风机系统故障诊断研究,E-mail:zhengjin@tpri.com.cn
  • 基金资助:
    陕西省重点研发计划资助项目(电站风机在线智能监测及专家诊断系统,2018ZDXM-GY-028)。

Cause Analysis and Related Solution of Induced Fan Vibrations in 300 MW Generation Unit Following the Integration of Induced Fans and Booster Fans

XUE Xiang1, QIU Yong1, MA Xiang2, ZHENG Jin2, LI Kailun2, ZHANG Zhenmin1   

  1. 1. PowerChina Turbo Technologies Co., Ltd., Chengdu 610054, China;
    2. Xi'an Thermal Power Research Institute Co., Ltd., Xi'an 710032, China
  • Received:2018-09-30 Revised:2018-12-29 Online:2019-06-05 Published:2019-07-02
  • Supported by:
    This work is supported by the Key Research & Development Program of Shaanxi Province (Online Intelligent Monitoring and Expert Diagnosis System for Power Station Fans, No.2018ZDXM-GY-028).

摘要: 针对某火电厂330 MW机组双级动叶可调式轴流风机振动过程进行详细描述,并通过热态试验、解体检修及现场振动测试对引起风机振动原因进行详细分析。结合振动现象、数据测试及振动故障诊断找到引起风机振动的主要原因,并提出解决方案,从根本消除了风机振动。研究结果对于大型燃煤发电机组双级动叶可调轴流风机改造,特别是目前广泛应用的引增合一风机的安全运行工作有指导意义。

关键词: 燃煤电厂, 风机, 振动, 故障诊断

Abstract: The vibration problems of induced fans with two-stage adjustable rotor blades in a 300 MW power generation unit are described in details. By virtue of hot test, disassembly overhaul and onsite vibration test, the causes of vibrations are analyzed. By taking account of the observations during the vibration process, the data testing and the fault diagnosis all together, the culprit of vibration is figured out and corresponding solutions are proposed. Consequently, the root cause of vibration is eliminated fundamentally. The study result can provide reference for the retrofit and secure operation of axial fans with two-stage adjustable rotor blades in coal-fired generating units.

Key words: coal-fired power plant, fan, vibration, fault diagnosis

中图分类号: