Electric Power ›› 2019, Vol. 52 ›› Issue (7): 117-122.DOI: 10.11930/j.issn.1004-9649.201811102

Previous Articles     Next Articles

Mechanism Analysis and Treatment of Blade Passing Frequency Vibration for Axial Induced Draft Fans in Power Plant

XU Jian1, XIA Xiaofei2, LI Kailun3, ZHENG Jin3, WANG Xing3, MA Xiang3   

  1. 1. China Resources Power Holdings Co., Ltd., Shenzhen 518000, China;
    2. Jiangsu Sheyang Power Generation Co., Ltd., Yancheng 224300, China;
    3. Xi'an Thermal Power Research Institute Co., Ltd., Xi'an 710032, China
  • Received:2018-11-26 Revised:2019-02-28 Online:2019-07-05 Published:2019-07-13
  • Supported by:
    This work is supported by the Key Research & Development Program of Shaanxi Province (Online Intelligent Monitoring and Expert Diagnosis System for Power Station Fans, No.2018ZDXM-GY-028).

Abstract: Based on extensive investigation and literature review, this paper systematically explored the blade passing frequency problem in the axial induced draft fans with the vibration amplitude exceeding the related standards, which has occurred widely in coal-fired power plants after the environmental transformation project implemented. Through the studies on a typical case in a domestic plant, the internal mechanism and treatment processes are analyzed in details. The study result shows that blade tip clearance evenness, casing roundness, blade synchronicity, blade shape consistency, impeller balance, and export flue forms all contribute to this vibration. At last, the treatment plan corresponding to the various causes of the vibration are put forward respectively. The research results and management experience presented are applicable to the blade passing frequency vibration treatment for axial induced draft fans in power plants.

Key words: coal-fired power plant, fan vibration, blade passing frequency, axial induced draft fan

CLC Number: