Abstract: The effect of the wastewater evaporation in flue duct to the flue gas dew point was studied in this article. Pilot test of the wastewater evaporation was conducted on a 600 MW unit. The H2O and SO3 contents in the flue gas were detected and the dew point was calculated using different formulas. The results showed that, when 900~1 400 L/h wastewater was injected in 1/4 flue duct of the 600 MW unit (the amount of flue gas was 4×105~5×105 m3/h), the water vapor in the flue gas increased 0.7%~0.9%, whereas the SO3 decreased by 30%~50%, which indicated that the transformation from SO3 to sulfuric acid mist and their adsorption on fly ash particles were improved after the wastewater evaporation. The flue gas dew point decreased by 9~14 ℃ after the evaporation, and the flue gas temperature could be higher than the dew point. Thus, wastewater evaporation in flue duct could not lead to low-temperature corrosion of the downstream ducts and equipments under the condition of pilot test.

Key words: coal-fired unit, desulfurization wastewater, flue duct evaporation, acid dew point, SO3

CLC Number: