Electric Power ›› 2017, Vol. 50 ›› Issue (10): 136-139.DOI: 10.11930/j.issn.1004-9649.201707168

• Energy Conservation and Environmental Protection • Previous Articles     Next Articles

Test and Study on Synergic Mercury Removal Performance of Environmental Protection Facilities at Ultra-Low Pollutants Emission

CUI Liming1, HUANG Zhijie2, 3, MO Hua2, ZHU Jie4, JIANG An2, HUANG Ru2   

  1. 1. Shenhua Group Co., Ltd., Beijing 100011, China;
    2. Appraisal Center for Environment & Engineering, Ministry of Environmental Protection, Beijing 100122, China;;
    3. Fujian Longking Environmental Protection Co., Ltd, Longyan 364000, China;
    4. Northeast Electric Power Design Institute of CPECC, Changchun 130021, China
  • Received:2017-06-16 Online:2017-10-25 Published:2017-10-30

Abstract: The test on mercury emission and distribution is carried out synchronously at multi-points in some ultra-low pollutants emission power plants. It is discovered that the mercury removal efficiency by WFGD is about 22.2%~80.35% and that by WESP is about 0%~71.4%. The mercury removal efficiency by WFGD is correlative to the mercury morphology at the entrance of WFGD, the unit load and the gas-liquid mass. WESP shows limit effect on the mercury capture when the mercury concentration at the entrance of WESP is low.

Key words: coal-fired power generation unit, thermal power generation, flue gas, ultra-low emission, synergism, mercury capture

CLC Number: