journal1 ›› 2015, Vol. 48 ›› Issue (8): 17-19.DOI: 10.11930/j.issn.10.11930.2015.8.17

• Column of Flue Gas Dust Removal • Previous Articles     Next Articles

A Case Study of Economic Comparison between Low-Low Temperature Dust Removal Technique and Electric- Baghouse Combined Dust Removal Technique in the 300-MW Unit Improvement

WANG Jianfeng, LI Yan, ZHANG Yang, ZHU Yue   

  1. China Huadian Electric Research Institute, Hangzhou 310030, China
  • Received:2015-05-13 Online:2015-11-25 Published:2015-08-25

Abstract: In this paper, the technical economic performance of low-low temperature electrostatic precipitator(ESP) and combined electro-bag filter are compared for the improvement of the 300-MW coal-fired boiler of a power plant. The comparison result shows that the low-low temperature ESP has the advantages of better adaptability to different flue-loads, more energy saving, emission reduction and no solid emissions. The installation of low-low temperature ESP will take more effort than the combined eletro-bag filter although the investment expenses of these two technologies are approximately the same. Therefore the unit costs of low-low temperature ESP is lower than that of the combined eletro-bag filter.

Key words: coal-fired power, dust removal, technical analysis, economic analysis

CLC Number: