Electric Power ›› 2015, Vol. 48 ›› Issue (4): 23-26.DOI: 10.11930/j.issn.10.11930.2015.4.23

• Column of Flue Gas Denilralion • Previous Articles     Next Articles

Influence of SNCR System on CFB Boiler Operation

YANG Yonglong1, ZHAO Kai2, SU Qiufeng3, ZHANG Yang1, WANG Fengji1, ZHU Yue1   

  1. 1. Huadian Electric Power Research Institute, Hangzhou 310030, China;
    2. Huadian Tianjin Junliangcheng Power Generation Co., Ltd., Tianjin 300300, China;
    3. State Key Laboratory of Clean Energy Utilization of Zhejiang University, Hangzhou 310027, China
  • Received:2015-01-13 Online:2015-12-03 Published:2015-04-25
  • Contact: 中国华电工程(集团)有限公司科技项目:失活SCR催化剂再生与循环回收利用技术的研发(CHEC-KJ-2011-39)

Abstract: In this paper, the performance testing of a CFB boiler is introduced. And then through the testing, the impact of SNCR system on CFB boiler operation is analyzed. The results show that the deNOx efficiency of SNCR system can reach over 60%. High ammonia slip will accelerate the block of air preheater by fly ash. The interaction between the slipped ammonia and SO3 can cause fouling at the low-temperature end of the air preheater, which makes the resistance of the air preheater increase, but on the other hand it may lower the emission concentrations of ammonia slip and SO3.

Key words: thermal power plant, SNCR, CFB boiler, ammonia slip, deNOx efficiency

CLC Number: