[1] 汪涛, 吴光亚, 张锐, 等. 运行中复合绝缘子的状态评价及试验研究[J]. 电网技术, 2008. 32(1): 146-149.WANG Tao, WU Guang-ya, ZHANG Rui, et al. State evaluation for the composite insulators’ status in operational mode and its experimental study[J]. Power System Technology, 2008. 32(1): 146-149.
[2] FERNANDO M A R M, GUBANSKI S M. Ageing of silicone rubber insulators in coastal and inland tropical environment[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2010, 17(2): 326-333.
[3] XIONG Y, ROWLAND S M, ROBERTSON J, et al. Surface analysis of asymmetrically aged 400 kV silicone rubber composite insulators[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008, 15(3): 763-770.
[4] ROWLAND S M, ROBERTSON J, XIONG Y, et al. Electrical and material characterization of field-aged 400 kV silicone rubber composite insulators[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2010, 17(2): 375-383.
[5] 范建斌, 殷禹, 张锦秀, 等. 复合绝缘子运行状况评估方法[J]. 电网技术, 2006, 30(12): 24-28.FAN Jianbin, YIN Yu, ZHANG Jinxiu, et al. Evaluation methods for operational status of composite insulators[J]. Power System Technology, 2006. 30(12): 24-28.
[6] 阎东、卢明、张柯, 等. 输电线路用复合绝缘子运行及实例分析[M]. 北京: 中国电力出版社, 2008.
[7] 张锐, 吴光亚, 袁田, 等. 中国复合绝缘子关键制造技术的发展与展望[J]. 高电压技术, 2007, 33(1): 106-110.ZHANG Rui, WU Guangya, YUAN Tian, et al. Development history and direction of composite insulators on important manufacture technique[J]. High Voltage Engineering, 2007, 33(1): 106-110.
[8] 崔江流, 宿志一, 易辉. 中国硅橡胶合成绝缘子的应用与展望[J]. 中国电力, 1999, 32(1): 38-41.CUI Jiangliu, SU Zhiyi, YI Hui. The application and its prospect of silicon rubber composite insulators in China[J]. Electric Power, 1999, 32(1): 38-41.
[9] CIGRE W G 22. 03. Electric: worldwide service experience with HV composite insulators[R], 1999.
[10] 徐其迎, 李日隆. 复合绝缘子的运行性能及问题探讨[J]. 电瓷避雷器, 2003(3).XU Qiying, LI Rilong. Analysis and discussion on composite insulator in service[J]. Insulators And Surge Arresters, 2003(3): 14-19.
[11] 关志成, 王黎明, 周远翔, 等. 复合绝缘子用于高海拔区750 kV线路的可行性[J]. 高电压技术, 2002, 28(2): 34-36.GUAN Zhicheng, WANG Liming, ZHOU Yuanxiang, et al. The Feasibility of application of composite insulator in 750 kV lines in high altitude area[J]. High Voltage Engineering, 2002, 28(2): 34-36.
[12] 阎东, 卢明, 张柯, 等. 河南省线路用复合绝缘子运行情况分析[J]. 电网技术, 2006, 30(12): 79-82.YAN Dong, LU Ming, ZHANG Ke, et al. Assessment on operation characteristics of composite insulators used for transmission line in Henan provincial power network[J]. Power System Technology, 2006, 30(12): 79-82.
[13] 刘贞瑶, 梁家鹏. 江苏电网2006年复合绝缘子运行及故障情况分析[J]. 江苏电机工程, 2007, 26(3): 50-53.LIU Zhenyao, LIANG Jiapeng. Analysis of composite insulator operation and fault situation in 2006 for Jiangsu power grid[J]. Jiangsu Electrical Engineering, 2007, 26(3): 50-53.
[14] 关志成. 绝缘子及输变电设备外绝缘[M]. 北京: 清华大学出版社, 2006.
[15] 李宝泉, 王伟, 陈志彦, 等. 河北南部电网运行合成绝缘子抽检试验分析[J]. 河北电力技术, 2000, 19(4): 8-10.LI Baoquan, WANG Wei, CHEN Zhiyan, et al. Test and analysis of composite insulators running in Hebei southern power grid[J]. Hebei Electrical Engineering, 2000, 19(4): 8-10.
[16] 仲伟涛, 刘伟, 王春玉. 运行中合成绝缘子的问题分析与试验研究[J]. 黑龙江电力, 2007, 29(1): 30-35.ZHONG Weitao, LIU Wei, WANG Chunyu. Trouble analysis and research of composite insulator in operation[J]. Heilongjiang Electric Power, 2007, 29(1): 30-35.
[17] 陈原, 刘燕生, 沈健, 等. 复合绝缘子隐蔽性缺陷检测方法[J]. 电网技术, 2006, 30(12): 58-63.CHEN Yuan, LIU Yansheng, SHEN Jian, et al. Inner-defect detection method for composite insulators[J]. Power System Technology, 2006, 30(12): 58-63.
[18] 粟福珩, 贾逸梅, 王青霞, 等. 陡波试验寻找合成绝缘子内部缺陷有效性的检验[J]. 电网技术, 2003, 27(1): 41-43.SU Fuheng, JIA Yimei, WANG Qingxia, et al. Verification on effectiveness of steep-front wave impulse voltage test to find internal defects inside composite insulators[J]. Power System Technology, 2003, 27(1): 41-43.
[19] SU Fuheng, JIA Yimei. Faults of composite insulators in service and research of on-line detection method[C]//Eleventh lnternational Symposium on. Hight Voltage Engineering, IET, 1999: 208-211.
[20] 党会学, 赵均海, 吴静. V形复合绝缘子力学特性研究[J]. 中国电力, 2016, 49(7): 9-14.DANG Huixue, ZHAO Junhai, WU Jing. Characteristic study for windage yaw analysis of V-shape composite insulator string[J]. Electric Power, 2016, 49(7): 9-14.
[21] 李鹏, 马斌, 刘道辉, 等. 紫外线老化对复合绝缘子硅橡胶憎水性的影响[J]. 中国电力, 2015, 48(3): 80-83.LI Peng, MA Bin, LIU Daohui, et al. Influence of ultraviolet radiation aging on hydrophobicity of silicone rubber used for composite insulator[J]. Electric Power, 2015, 48(3): 80-83. |