典型燃煤电厂浆液冷却烟气消白设施SO3治理效果测试研究

吴家玉1, 朱杰2, 莫华1, 张峰3, 帅伟1, 张晴1, 那钦4   

  1. 1. 生态环境部环境工程评估中心,北京 100012;
    2. 中国电力工程顾问集团中南电力设计院有限公司,湖北 武汉 430071;
    3. 徐州铜山华润电力有限公司,江苏 徐州 221142;
    4. 内蒙古电力科学研究院,内蒙古 呼和浩特 010020
  • 收稿日期:2020-04-22 修回日期:2020-05-11 发布日期:2020-08-05
  • 作者简介:吴家玉(1983-),男,高级工程师,从事电力环境保护政策与管理研究,E-mail:wujy@acee.org.cn;莫华(1969-),女,通信作者,高级工程师(教授级),从事电力环境影响评估、环境保护政策与管理研究,E-mail:mohua@acee.org.cn

Test Study on SO3 Control Effect of Slurry Cooling Wet Plume Treatment Project in a Typical Coal-Fired Power Plant

WU Jiayu1, ZHU Jie2, MO Hua1, ZHANG Feng3, SHUAI Wei1, ZHANG Qing1, NA Qin4   

  1. 1. Appraisal Center for Environment & Engineering, Ministry of Ecology and Environment of P.R.C, Beijing 100012, China;
    2. Central South Electric Power Design Institute of CPECC, Wuhan 430071, China;
    3. China Resources Power (Xuzhou/Tongshan) Co., Ltd., Xuzhou 221142, China;
    4. Inner Mongolia Power Research Institute, Huhhot 010020, China
  • Received:2020-04-22 Revised:2020-05-11 Published:2020-08-05

摘要: 分别采用控制冷凝法和异丙醇吸收法对某1 000 MW燃煤发电机组浆液冷却烟气消白设施的烟气SO3控制效果开展测试。结果表明,机组烟气湿法脱硫设施对SO3去除效率为62.50%(控制冷凝法)和64.63%(异丙醇吸收法)。烟气经现有超低排放设施协同治理后SO3质量浓度低于3 mg/m3。浆液冷却设施对SO3的去除效率仅为6.68%(控制冷凝法)和5.55%(异丙醇吸收法),烟气SO3控制效果和环境效益相对较低。建议基于科学论证审慎实施燃煤电厂烟气消白工作,应进一步开展高效SO3治理技术、测试标准和环境管理政策研究。

关键词: 超低排放, 消白, 浆液冷却, SO3, 控制冷凝法, 异丙醇吸收法

Abstract: In this paper, the SO3 control effect of the slurry cooling wet plume treatment project is tested and evaluated. With the controlled condensation method and the isopropanol absorption method applied respectively in a 1 000 MW coal-fired power generation unit, the testing results show that the SO3 removal efficiency of the wet flue gas desulfurization (WFGD) system reaches 62.50% and 64.63% accordingly. The SO3 mass concentrations of the flue gas can be controlled under 3 mg/m3 with current ultra-low flue gas emission treatment facilities. However, using the same controlled condensation method and the isopropanol absorption method, the SO3 removal efficiency of the slurry cooling wet plume treatment project is only 6.68% and 5.55%, respectively, which indicates unsatisfactory SO3 control effect and relatively low environmental benefit. At last, it is suggested that the wet plume treatment of coal-fired generation plants should be implemented with great caution and on the basis of scientific verifications. Further studies are needed for efficient SO3 control techniques, SO3 testing benchmarks and related environmental management policies.

Key words: ultra-low emission, wet plume treatment project, slurry cooling, SO3, controlled condensation method, isopropanol absorption method