Electric Power ›› 2014, Vol. 47 ›› Issue (10): 117-121.DOI: 10.11930/j.issn.1004-9649.2014.10.117.4

• Generation Technology • Previous Articles     Next Articles

Research and Application on Low-Low Temperature Electrostatic Precipitator Technology

ZHAO Hai-bao, LI Jian-guo, HE Yu-zhong, YAO Yu-ping   

  1. Zhejiang Feida Environmental Science & Technology Co., Ltd., Zhuji 311800, China
  • Received:2014-03-18 Online:2014-10-18 Published:2015-12-10
  • Supported by:
    This work is supported by the Research and Demonstration Project on Low-Low Temperature Electrostatic Precipitator Technology and Recycling of Waste Heat System (2013C01054)

Abstract: As a new dust removal technology, the low-low temperature electrostatic precipitator (LLT-ESP) has the advantages of low energy consumption and high SO3 removal efficiency and has become the mainstream method in flue gas treatment in Japan. However, studies on the LLT-ESP performance are few in China. In this paper, the analysis on the coal adaptability, acid dew point, D/S ratio (the concentration ratio of PM to SO3 solution as H2SO4), dust re-entrainment and off-line rapping technique is conducted and the D/S ratio formula is proposed. The influencing amplitude of D/S ratio on the corrosion and dust removal efficiency of typical LLT-ESP and the application of combining mobile electrode with LLT-ESP are studied. At the end, some of the most representative LLT-ESPs which will be launched in China are introduced.

Key words: boiler, LLT-ESP, performance, D/S ratio, off-line rapping technique, SO3 removal

CLC Number: