Abnormal Vibration Diagnostic Methods of Transformers Caused by Two Defects

HAO Zhen1, LONG Kai-hua1, ZHAO Yan-kun1, WU Yan-wei1, LU Wei2   

  1. 1. Research Institute, State Grid Jibei Electric Power CO., LTD., Beijing 100045, China;
    2. Beijing Jingxi Gas-fired Thermal Power CO., LTD., Beijing 100041, China
  • Revised:2014-01-10 Online:2014-06-18 Published:2015-12-08

Abstract: Iron cores and windings are the key components of power transformers, which are also the causes of transformers vibrations. By loosing a fastening device to stimulate abnormal vibration and installing seven sensors in the internal and external of a transformer to research the differences between internal and external data, a 10 kV transformer defect model was established in a laboratory, which can obtain the best sensor arrangement for measuring transformer vibrations. By studying the vibration laws of cores windings respectively at different no-load voltages and load currents, eventually come the methods for the diagnosis of transformer core and winding looses.

Key words: transformer, core, winding, vibration test