Electric Power ›› 2012, Vol. 45 ›› Issue (10): 52-55.DOI: 10.11930/j.issn.1004-9649.2012.10.52.3

• Generalion Technology • Previous Articles     Next Articles

Analysis and Practice of Allowance -Reducing Technology for FGD Booster Fan of Thermal Power Plants

LIANG Shuang-yin1, LI Ji-mao1, HOU Yun-hao2, GAO Xin-xi2, JIA Li-sheng2, ZHAO Yan-jun1   

  1. 1. School of Energy Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China;
    2. North United Power Corporation, Hohhot 010020, China
  • Received:2012-06-16 Online:2012-10-18 Published:2016-02-29

Abstract: In view of the excessive allowance and low operating efficiency existing in FGD booster fans of thermal power plants, the transformation idea of reducing the allowance and raising the efficiency is put forward. Calculations and analyses for the FGD booster fan for a 200-MW unit are carried out, which indicates that the allowance of the fan is excessive and the operating efficiency is low. Therefore, a scheme for slowing down the speed and eliminating the allowance is promoted with the feasibility and economics being analyzed. After the transformation, operation indicates that the service power rate is reduced by 0.22%, which is very remarkable in energy-saving.

Key words: thermal power plant, FGD booster fan, speed-reducing and allowance-reducing, energy-saving transformation