中国电力 ›› 2015, Vol. 48 ›› Issue (4): 101-106.DOI: 10.11930.2015.4.101

• 电网 • 上一篇    下一篇

基于多个广域测量系统的联合低频振荡分析和监测

段刚1,詹庆才1,杨东1,谢晓冬1,吴京涛1,肖小刚2,王健2,刘涛2   

  1. 1. 北京四方继保自动化股份有限公司,北京 100085;
    2. 国家电网华中电力调控分中心,湖北 武汉 430077
  • 收稿日期:2015-01-04 出版日期:2015-04-25 发布日期:2015-12-03
  • 作者简介:段刚(1972—),男,山东烟台人,博士,高级工程师,从事广域测量系统和智能电网调度自动化研究。E-mail: duangang@sf-auto.com

Multiple WAMS-Based Coordinated Analysis and Monitoring of Low Frequency Oscillations

DUAN Gang1, ZHAN Qingcai1, YANG Dong1, XIE Xiaodong1, WU Jingtao1, XIAO Xiaogang2,WANG Jian2, LIU Tao2   

  1. 1. Beijing Sifang Automation Co., Ltd., Beijing 100085, China;
    2. Center China Power Grid Company, Wuhan 430077, China
  • Received:2015-01-04 Online:2015-04-25 Published:2015-12-03

摘要: 为提高XLPE电缆绝缘诊断精度,将信息融合技术用于其中。针对D-S证据理论中各绝缘参数可信度分配难以确定的问题,提出模糊理论与证据理论相结合的绝缘诊断方法,建立基于模糊理论的证据融合诊断模型,该模型将模糊理论中的模糊集合与隶属度函数概念运用于证据理论,利用隶属度函数构造证据理论的合理信度函数分配,在此基础上联合每个绝缘参数的可信度形成最终的融合结果。实例分析表明了该诊断模型的有效性。

关键词: XLPE电缆, 绝缘诊断, 信息融合, D-S证据理论, 模糊理论

Abstract: For low frequency oscillation spanning several control areas, local WAMS cannot identify the oscillation mode if only according to the information obtained in its own control area. A coordinated analysis and monitoring method for low frequency oscillations is proposed based on the information from several wide Area Measurement Systems (WAMS). For the power system with several WAMS control centers, one of the control centers is selected as the master WAMS, the others are treated as slave WAMS. In case that one of the WAMS detects a dangerous low frequency oscillation occurring in its control area, it will trig the coordinated analysis of low frequency oscillation based on the data from all WAMS. The slave WAMSs make frequency analysis of their own measurements respectively, and send the results to the master station. The master station synchronizes the analysis results from different WAMS and different frequency analysis methods, and then makes coherent group of the buses and calculate the relative contributions of key buses to the power oscillation. The analysis result is then returned to the slave WAMS. By this method, each control center can clearly understand its role in a wide area when low frequency oscillation involves several control centers, which will help to control the low frequency oscillation.

Key words: wide area measurement system, phasor measurement unit, low frequency oscillation, coherent grouping, frequency analysis, coordinated analysis, integrated alarm

中图分类号: