Electric Power ›› 2016, Vol. 49 ›› Issue (1): 19-22.DOI: 10.11930/j.issn.1004-9649.2016.01.019.04

• Generation Technology • Previous Articles     Next Articles

Reheat Steam Temperature Control of an Ultra Supercritical Unit with Second Reheat Cycle

YANG Xinmin1, WU Hengyun1, MAO Yijun2   

  1. 1. Xi’an Thermal Power Research Institute Co., Ltd., Xi’an 710032, China;
    2. Huaneng Anyuan Power Plant, Pingxiang 337016, China
  • Received:2015-06-01 Online:2016-01-18 Published:2016-02-04

Abstract: In this paper, taking the 660-MW ultra supercritical unit with second reheat cycle of Anyuan Power Plant as the study object, through the analysis on the static characteristics with single factor variation of reheat steam temperature controls, the control schemes of primary and secondary reheat steam temperatures are proposed. The onsite operation practices show that the schemes can meet the operation requirements under various loads and RB working conditions.

Key words: automatic control, reheat steam temperature, secondary reheat, flue gas recirculation

CLC Number: