Electric Power ›› 2014, Vol. 47 ›› Issue (3): 48-54.DOI: 10.11930/j.issn.1004-9649.2014.3.48.6

• Orginal Article • Previous Articles     Next Articles

Analysis and Comparison to the Correction Method of Boiler Thermal Efficiency Based on GB 10184-88 Codes

LI Yong, HAN Wei, WANG Yan-hong   

  1. School of Energy and Power Engineering, Northeast Dianli University, Jilin 132012, China
  • Received:2013-12-08 Online:2014-03-31 Published:2015-12-18

Abstract: Boiler thermal efficiency is an important indicator to evaluate the economic efficiency of thermal power unit in operation. When a parameter changes, the existing correction method of boiler thermal efficiency is inconvenient to analyze its influence to the boiler thermal efficiency, and it is also inconvenient to analyze the reason and location which cause the reduction of the boiler thermal efficiency in operation. A new correction method which combined differential deviation method with first order Taylor formula was proposed to revise the various losses and boiler thermal efficiency, and comparison and analysis of correction calculation method were also conducted between the innovative correction method and the Chinese Utility Boiler Performance Test Code GB 10184—88. Taking a 1025 t/h boiler for example, various losses and boiler thermal efficiency were calculated under two different test conditions, The results show that the difference of the losses and boiler thermal efficiency calculated on differential modification method and GB 10184—88 codes is tiny after modification, so this method can be applied into the engineering practice.

Key words: boiler thermal efficiency, correction calculation, GB 10184—88 codes, economic diagnosis

CLC Number: