Electric Power ›› 2012, Vol. 45 ›› Issue (2): 22-25.DOI: 10.11930/j.issn.1004-9649.2012.2.22.3

• Generation Technology • Previous Articles     Next Articles

Off-design characteristics of condenser in direct air-cooling 1 000 MW unit

HAN Zhong-he1, ZHENG Qing-yu1, WU Zhi-quan2, WANG Zhi1   

  1. 1. Key Laboratory of Condition Monitoring and Control for Power Plant Equipment of Ministry of Education, North China Electric Power University, Baoding 071003, China;
    2.China National Water Resources &
    Electric Power Materials &
    Equipment Co., Ltd., Beijing 100045,China
  • Received:2011-08-16 Revised:2011-12-02 Online:2016-02-29 Published:2012-02-18

Abstract: Taking 1 000 MW direct air cooling units as an example, by using the method of effective energy-heat transfer units, a mathematical model of direct air cooling units under variable operating conditions has been elaborated. By considering the influence of pressure drop of the exhaust pipe and environment heat dissipation loss on the exhaust steam pressure of the last stage in the steam turbine in direct air cooling units, the curves of condenser pressure change with environment temperature, face velocity and exhaust steam flow were obtained. The linear relationship between the exhaust steam pressure of the last stage and its influence factors was analyzed, which can provide a reference for choosing the suitable exhaust steam pressure and for improving economical efficiency under off-design operation conditions in 1 000 MW air-cooling units.

Key words: condenser pressure, direct air-cooling, off-design, characteristic curves