Electric Power ›› 2022, Vol. 55 ›› Issue (7): 42-48.DOI: 10.11930/j.issn.1004-9649.202009147

• Power System • Previous Articles     Next Articles

Comparison of Harmonic Current Limit Determination Methods Between GB/T 14549—93 and IEEE std.519:2014

SONG Yifan1, ZHAO He1, SHEN Junyan2, TAO Shun2, MA Xihuan2, XU Yonghai2   

  1. 1. State Grid Beijing Electric Power Research Institute, Beijing 100075, China;
    2. School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China
  • Received:2020-09-29 Revised:2022-04-01 Online:2022-07-28 Published:2022-07-20
  • Supported by:
    This work is supported by General Project of the National Natural Science Foundation of China (Analytical Modeling and Grid-Connection Interaction of Time-varying Harmonics in Wind Power Systems and Study of Hazard Zones, No.51777066)

Abstract: The allowable harmonic current limits injected to the common connection points are stipulated for users respectively by GB/T 14549—93 and IEEE std.519:2014. However, there are some differences between two standards in determination methods and engineering application. The harmonics national standard GB/T 14549 under revision intends to adopt the emission limits of harmonic current for single user in IEEE std.519:2014. Therefore, it is necessary to fully discuss the rationality of the methods for determining the harmonic current limits. In this paper, the limits of the harmonic current in two standards are introduced, and their determination methods are deduced and discussed respectively. Finally, the similarities and differences between them are analyzed through case study.

Key words: harmonic?standard, IEEE std.519:2014, GB/T 14549—93, current apportionment, harmonic current limit