Electric Power ›› 2018, Vol. 51 ›› Issue (9): 65-72.DOI: 10.11930/j.issn.1004-9649.201705052

Previous Articles     Next Articles

Application of Unified Power-Regulating System of Auxiliary Equipment on a 660 MW Unit

MU Chunhua1, LV Kai1,2, XU Pengjiang1,2, SUN Dawei1, WU Pengyue1, MA Tingshan1,2, JU Wenping1,2, LI Dongquan3   

  1. 1. Xi'an Thermal Power Research Institute Co., Ltd., Xi'an 710054, China;
    2. Xi'an TPRI Energy Conservation Technology Co., Ltd., Xi'an 710054, China;
    3. Huaneng Weihai Power Generation Co., Ltd., Weihai 264299, China
  • Received:2017-05-15 Revised:2018-06-22 Online:2018-09-05 Published:2018-09-20
  • Supported by:
    This work is supported by Science and Technology Project of China Huaneng Group (No.HNKJ15-H09).

Abstract: The unified power-regulating system of auxiliary equipment (UPRS), which is mainly composed of variable-high-speed turbine and variable-frequency generator, adjusts the main auxiliary equipment with the same optimum operating frequency. It reduces the throttle loss of the system and improves the transmission efficiency, while the system is more centralized, simple and easy to maintain. A power source system of boiler fan driven by frequency conversion is adopted in a 660MW unit. The operating characteristics of the system are figured out through performance tests, and the optimal operating modes under different loads are also obtained. The best operating frequencies under THA, 75%THA and 50%THA operating conditions are 47Hz, 41Hz and 41Hz, respectively. Within the range of frequency 41~50Hz, the coal consumption of the unit when the power source system is operated under the optimal frequency is slightly less than or basically equal to that under the operation frequency before the transformation, and is slightly more than that with the variable frequency operation state, but the power consumption rate of the unit decreases significantly, and the net power supply capacity is also significantly improved. With the decrease of operating frequency, the efficiency of induced fan, primary fan and blower are improved to some extent. The total power consumption of the three blower fans is approximately linear with the operating frequency. The operating frequency is reduced from 50Hz to the optimal point, the total energy consumption is reduced by 308kW/816kW and 868kW respectively under the condition of 75THA and 50%THA.

Key words: coal-fired power units, variable-high-speed turbine, variable-frequency generator, unified power-regulating system of auxiliary equipment, uniformly regulate, operating efficiency, coal consumption of power supply