Electric Power ›› 2017, Vol. 50 ›› Issue (8): 63-67.DOI: 10.11930/j.issn.1004-9649.2017.08.063.05

• Generation Technology • Previous Articles     Next Articles

Research on Operation of Swirl-Opposed Firing Boiler Retrofitted for Low NOx Emission

LIU Qingwei, GUO Zhiming, LU Ye, REN Lili, DU Daquan   

  1. Beijing Guodianlong High-Tech Environmental Engineering & Technology Co., Ltd., Beijing 100035, China
  • Received:2017-01-06 Online:2017-08-25 Published:2017-08-25

Abstract: The emission of NOx decreased obviously after the transformation with low NOx burner (LNB) for a 600 MW unit. However, there are some problems during the process in operation, such as overheating of the reheater, the high oxygen deviation and the high NOx emission under high power loads. The problems are discussed in this paper and some improvement measures are proposed to ensure the efficiency and safety of LNB.

Key words: coal-fired generation, boiler, burner retrofitting, over-fire air, central-fuel-rich swirl coal combustion burner, recirculation zone, ignition-point

CLC Number: