Electric Power ›› 2017, Vol. 50 ›› Issue (12): 173-177.DOI: 10.11930/j.issn.1004-9649.201608057

• Energy Conservation and Environmental Protection • Previous Articles     Next Articles

The Application and Performance Evalution of Bundle Precipitator in Series Absorpti Tower of Desnifurization System

YOU Liangzhou, DU Zhen, JIANG Jianping, ZHU Yue   

  1. China Huadian Electric Reaesrch Institute, Hangzhou 310030, China
  • Received:2016-08-26 Revised:2017-08-09 Online:2017-12-20 Published:2018-01-30
  • Supported by:
    This work is supported by National Key Research Program of China(No. 2016YFC0203701-5).

Abstract: To achieve the target of ultra-low emissions, the original defogger was replaced with a tube bundle precipitator in the 670 MW coal-fired units. In this paper, by tuning the electric fabric filter bypass opening and desulfurization spray level system operating mode, the overall coordination cleaning efficiency of desulfurization system was tested under various working conditions. According to the test results, the tube bundle type dust collector exhibits higher efficiency under high-load conditions. However, under low load conditions, the efficiency drops down drastically and the slurry droplet concentration goes up. Especially, the spray layer operation mode has great impacts on the dust washing effect.

Key words: coal-fired units, bundle precipitator, desulfurization cascade system, low-load conditions, performance evalution

CLC Number: