[1] 严陆光. 大力发展高电压、长距离、大容量高温超导输电的建议[J]. 电工电能新技术,2006,25(1):1-4. YAN Luguang. A proposal for development of high voltage, long distance, high capacity, high temperature superconducting power transmission [J]. Adv. Tech. of Elec. Eng. & Energy, 2006, 25(1): 1-4. [2] 戴武昌,陈东魁,张威,等. 大容量远距离交流输电系统无功平衡及稳态电压控制[J]. 电网技术,2013,37(4):1101-1105. DAI Wuchang, CHEN Dongkui, ZHANG Wei, et al. Reactive power balance and steady voltage control of large-scale long- distance AC transmission system[J]. Power System Technology, 2013, 37(4): 1101-1105. [3] 吴田,阮江军,胡毅,等. 500 kV输电线路的山火击穿特性及机制研究[J]. 中国电机工程学报,2011,31(34):163-170. WU Tian, RUAN Jiangjun, HU Yi, et al. Study on forest fire induced breakdown characteristics and mechanism of 500 kV transmission line[J]. Proceedings of the CSEE, 2011, 31(34): 163-170. [4] 普子恒,阮江军,黄道春,等. 火焰条件下间隙的直流电压击穿特性研究[J]. 中国电机工程学报,2014,34(3):453-459. PU Ziheng, RUAN Jiangjun, HUANG Daochun, et al. Study on DC voltage breakdown characteristic of gap under fire conditions[J]. Proceedings of the CSEE, 2014, 34(3): 453-459. [5] ROBLEDO M A, GUZMAN E, HERNANDEZ J L. Dielectric characteristics of a model transmission line in the presence of fire[J]. IEEE Trans on Electrical Insulation, 1991, 26(4): 776-782. [6] KOUFAKIS E I, TSARABARIS P T, STYLIANOS J, et al. A wildfire model for the estimation of the temperature rise of an overhead line conductor [J]. IEEE Trans on Power Delivery, 2010, 25(2): 1077-1082. [7] 杨立红,杨明玉. 基于固有频率的高压直流输电线路故障测距[J]. 中国电力,2013,46(7):82-86. YANG Lihong, YANG Mingyu. Fault-location method for HVDC transmission lines based on natural frequency[J]. Electric Power,2013, 46(7): 82-86. [8] 王彩芝,姜映辉,王俊江,等. 基于PSCAD/EMTDC的HVDC接地极线路故障仿真[J]. 中国电力,2014,47(2):69-72. WANG Caizhi, JIANG Yinghui, WANG Junjiang, et al. PSCAD/EMTDC-based simulation research on HVDC grounding line fault[J]. Electric Power, 2014, 47(2): 69-72. [9] 王浩东. 输电线路山火跳闸原因分析及对策[J]. 广西电力,2009(4):43-45. WANG Haodong. Reason analysis and treatment of transmission linetrip because of mountain fire[J]. Guangxi Electric Power, 2009(4): 43-45. [10] 黄乐,舒双焰. 南方电网 2010年第一季度线路山火跳闸情况分析[J]. 广东电力,2011,24(3):95-97. HUANG Le, SHU Shuangyan. Analysis on fault trips caused by forest fire in CSG in the first quarter[J]. Guangdong Electric Power, 2011, 24(3): 95-97. [11] 胡湘,陆佳政,曾祥君,等. 输电线路山火跳闸原因分析及其防治措施探讨[J]. 电力科学与技术学报,2010,25(2):73-78. HU Xiang, LU Jiazheng, ZENG Xiangjun, et al. Analysis on transmission line trip caused by mountain fire and discussion on tripping preventing measures[J]. Journal of Electric Power Science and Technology, 2010, 25(2): 73-78. [12] 吴田,阮江军,张云,等. 输电线路因山火跳闸事故统计特性与识别分析[J]. 电力系统保护与控制,2012,40(10):138-143. WU Tian, RUAN Jiangjun, ZHANG Yun, et al. Study on the statistic characteristics and identification of AC transmission line trips induced by forest fires[J]. Power System Protection and Control, 2012, 40(10): 138-143. [13] 吴田,胡毅,阮江军,等. 交流输电线路模型在山火条件下的击穿机理[J]. 高电压技术,2011,37(5):1115-1122. WU Tian, HU Yi, RUAN Jiangjun, et al. Air gap breakdown mechanism of model AC transmission line under forest fires[J]. High Voltage Engineering, 2011, 37(5): 1115-1122. [14] 尤飞,陈海翔,张林鹤,等. 木垛火导致高压输电线路跳闸的模拟实验研究[J]. 中国电机工程学报,2011,31(34):192-197. YOU Fei, CHEN Haixiang, ZHANG Linhe, et al. Experimental study on flashover of high-voltage transmission line induced by wood crib fire[J]. Proceedings of the CSEE, 2011, 31(34): 192-197. [15] 杨晓菡,卢国建,刘松林. 木垛暴露面积与其热释放速率关系的研究[J]. 消防理论研究,2010,29(1):13-15. YANG Xiaohan, LU Guojian, LIU Songlin. Study on the relationship between the exposed area of wood crib and its heat release rate [J]. Fire Science and Technology, 2010, 29(1): 13-15. [16] 张云,尤飞,陈海翔,等. 山火条件下高压输电线路放电特性[J]. 消防理论研究,2012,31(1):1-5. ZHANG Yun, YOU Fei, CHEN Haixiang, et al. Discharging characteristics of high voltage transmission line under the conditions of wild fire [J]. Fire Theoretical Research, 2012, 31(1): 1-5. |