Electric Power ›› 2013, Vol. 46 ›› Issue (5): 18-22.DOI: 10.11930/j.issn.1004-9649.2013.5.18.4

• Security column • Previous Articles     Next Articles

Anti-freezing and Pre-heating Measures for Radiator in Indirect Air-Cooling Units in Cold Areas

LIU Pei-zhong, YANG Zhi-jun   

  1. Xinjiang Zhundong Colorful Bay Power Branch Company, Changji 831700, China
  • Received:2012-12-09 Online:2013-05-05 Published:2015-12-14

Abstract: Radiator freezing is common in indirect air-cooling units in alpine regions. In order to improve the running security of the indirect air-cooling units in winter, in-depth analysis and research on freezing in sector radiator tubes are conducted, which concludes that the existing anti-freezing measures are inefficient in alpine regions. Therefore, a design for anti-freezing and pre-heating is proposed with anti-freezing measures and ice-melting methods for the radiator fin tube bundles presented. The new design can provide a safeguard for the secure and reliable operation of the indirect air-cooling units in alpine regions.

Key words: coal-fired generating unit, indirect air cooling, cold area, radiator, anti-freezing and pre-heating

CLC Number: