[1] MOHANA R, JOY T, SINGH B. Frequency characteristics of very fast transient current in a 245 kV GIS [J]. IEEE Transactions on Power Delivery, 2005, 20(4): 2450-2457. [2] MIRIZ A M. Electromagnetic phenomena in the secondary circuits of voltage and current transformers in GIS (measurements and calculations) [J]. IEEE Transactions on Power Delivery, 2001, 16 (4): 571-575. [3] WIGGINS C M, ETOMAS D, NICKEL F S. Transient electromagnetic interference in substation[J]. IEEE Transactions on Power Delivery, 1994, 9(4): 1869-1884. [4] KUMAR A, MAHESH K M. VFT study for EHV-GIS substation [C]//Fifteenth National Power Systems Conference(NPSC). IIT Bombay, 2008. [5] 刘卫东,汪林森,陈维江,等. 特高压GIS特快速暂态过电压试验重复击穿过程研究[J]. 高电压技术,2011,37(3):644-650. LIU Weidong, WANG Linsen, CHEN Weijiang, et al . Investigation of the VFTO related repeated breakdown processes in UHV GIS[J]. High Voltage Engineering, 2011, 37(3): 644-650. [6] 陈维江,颜湘莲,王绍武. 气体绝缘开关设备中特快速暂态过电压研究的新进展[J]. 中国电机工程学报,2011,31(31):1-11. CHEN Weijiang, YAN Xianglian, WANG Shaowu. Recent progress in investigations on VFTO in GIS[J]. Proceeding of the CSEE, 2011, 31(31): 1-11. [7] 史保壮,李智敏,张文元. 超高压GIS中快速暂态过电压造成危害的原因分析[J]. 电网技术,1998,22(1):1-3. SHI Baozhuang, LI Zhimin, ZHANG Wenyuan. Analysis of the reason why VFTO may endanger GIS above 300 kV[J]. Power System Technology, 1998, 22(1): 1-3. [8] 郑记玲. 252 kV GIS中隔离开关电弧模型的研究[D]. 北京:华北电力大学,2012. [9] 毛为民. 隔离开关操作引起失灵保护误动的分析[J]. 电力系统自动化,2002,7(3):74-76. MAO Weimin. Analysis on error actuation of protection caused by disconnector operation[J]. Automation of Electric Power Systems, 2002, 7(3): 74-76. [10] 田芸,吴细秀,张欢. VFTO计算中隔离开关燃弧模型探究[J]. 高压电器,2013,49(5):106-111. TIAN Yun, WU Xixiu, ZHANG Huan. Review on the arcing model for disconnectors in the calculation of VFTO[J]. High Voltage Apparatus, 2013, 49(5): 106-111. [11] 闫格,吴细秀,田芸,等. 开关电弧放电电磁暂态干扰研究综述[J]. 高压电器,2014,50(2):119-130. YAN Ge, WU Xixiu, TIAN Yun, et al . Review on the research of electromagnetic transient interference caused by discharge due to switchgear operation[J]. High Voltage Apparatus, 2014, 50(2): 119-130. [12] 邹建华,康宁,李成,等. 快速暂态过电压的形成机制与抑制方法[J]. 西安交通大学学报,2005,39(4):417-420. ZOU Jianhua, KANG Ning, LI Cheng, et al . Research on mechanism in formation and depressed of very fast transient overvoltage[J]. Journal of Xi’an Jiao Tong University, 2005, 39(4): 417-420. [13] 刘晓明,冷雪,曹云东,等. 550 kV SF 6 断路器气流与电弧相互作混沌研究[J]. 电工技术学报,2012,27(6):46-52. LIU Xiaoming, LENG Xue, CAO Yundong, et al . Chaotic characteristic analysis of the interaction between arc and gas flow of 550 kV SF 6 circuit breaker[J]. Transactions of China Electrotechnical Society, 2012, 27(6): 46-52. [14] 李志兵,李晓昂,陈维江,等. SF 6 短间隙中高频电弧的阻抗特性[J]. 高电压技术,2013,39(6):1411-1418. LI Zhibing, LI Xiaoang, CHEN Weijiang, et al . Impendence characteristic of high-frequency arc in short SF 6 gap[J]. High Voltage Engineering, 2013, 39(6): 1411-1418. [15] 钱家骊. 高压开关开合电容电流和小电感电流[M]. 北京:中国电力出版社,1999. [16] YANABU S, MURASE H, AOYAGI H. Estimation of fast transient overvoltage in GIS[J]. IEEE Transactions on Power Delivery, 1990, 5(4): 1875-1882. [17] LIN Xin, WANG Na. Dynamic arcing model of switching and its effect on VFTO[C]//1st International Conference on Electric Power Equipment-Switching Technology. Xi’an, 2011: 608-612. [18] MARTINEZ J A, CHOWDHURI P, et al . Modeling guidelines for very fast transients in GIS[J]. Power Engineering Review, 1996, 17(13): 71-95. [19] POVH D, SCHMITT H, VOLICKER O, et al . Modeling and analysis guidelines for very fast transients[J]. IEEE Transactions on Power Delivery, 1996, 11(4): 2028-2034. [20] 熊信银,张步涵. 电气工程基础[M]. 武汉:华中科技大学出版社,2005. [21] RAO M M, TOMAS M J, SINGH B P. Computation of EMI fields in a high voltage gas insulated substation during switching operations [C]//IEEE International Symposium on Electromagnetic Compatibility. Boston, USA, 2003. [22] 李清泉,李彦明,牛亚民. 变电站开关操作引起的瞬变电磁场及其防护[J]. 高电压技术,2001,27(4):35-37. LI Qingquan, LI Yanming, NIU Yamin. The transient eletromagnetic fields caused by the operation of disconnector in substation and protection [J]. High Voltage Engineering, 2001, 27 (4): 35-37. [23] 阮全荣,施围. GIS隔离开关带分合闸电阻抑制VFTO的研究[J]. 高电压技术,2005,31(12):6-8. RUAN Quanrong, SHI Wei. Suppression of VFTO by disconnector with opening and closing resistor in GIS[J]. High Voltage Engineering, 2005, 31(12): 6-8. [24] YAMAGATA Y, TANAKA K, NISHIWAKI S. Suppression of VFT in 1 100 kV GIS by adopting resistor-fitted disconnector [J].IEEE Transactionson Power Delivery, 1996, 11(2): 872-880. [25] 王磊. 750 kV变电站GIS设备VFTO特性研究[J]. 中国电力,2015,48(5):125-132. WANG Lei. Study on VFTO charateristics of GIS in 750 kV substation [J]. Electric Power, 2015, 48(5): 125-132. [26] 罗红涛,黄文武,邹洪民,等. GIS内部潜伏性故障案例分析[J].中国电力,2014,47(7):86-90. LUO Hongtao, HUANG Wenwu, ZOU Hongmin, et al . Case study on GIS internal latent fault [J]. Electric Power, 2014, 47(7): 86-90. [27] 王磊,陈洁,万磊,等. 特高压GIS变电站VFTO仿真计算研究[J]. 电力建设,2014,35(9):1-6. WANG Lei, CHEN Jie, WAN Lei, et al . VFTO Simulation study for UHV GIS substation[J]. Electric Power Construction, 2014, 35(9): 1-6. [28] 王娜,刘吉成,张浩. 特高压1 100 kV GIS用母线的研制[J]. 电力建设,2014,35(6):102-105. WANG Na, LIU Jicheng, ZHANG Hao. 1 100 kV UHV busbar development for GIS[J]. Electric Power Construction, 2014, 35(6): 102-105. [29] 曾雄杰,刘旭明,黄文武,等. 超声波局放监测在GIS耐压局放试验中的应用[J]. 中国电力,2014,47(8):13-20. ZENG Xiongjie, LIU Xuming, HUANG Wenwu, et al . Application of ultrasonic-based PD monitoring system in the test of withstanding voltage and PD [J]. Electric Power, 2014, 47(8): 13-20. [30] 贾志杰,张斌. GIS回路电阻超标缺陷定位分析[J]. 中国电力,2015,48(5):46-50. JIA Zhijie, ZHANG Bin. Location analysis of GIS circuit resistance defection [J]. Electric Power, 2015, 48(5): 46-50. |