中国电力 ›› 2016, Vol. 49 ›› Issue (8): 50-53.DOI: 10.11930/j.issn.1004-9649.2016.08.050.04

• 电网 • 上一篇    下一篇

应用微波消解-ICP-AES法测定变压器油中的金属元素

刘松涛,张晶,陈传敏,贾文波   

  1. 华北电力大学 环境科学与工程学院,河北 保定 071003
  • 收稿日期:2015-12-03 出版日期:2016-08-10 发布日期:2016-08-12
  • 作者简介:刘松涛(1980—),男,河南商丘人,副教授,从事环境工程教学与研究。

Determination of Metal Elements in Transformer Oil with ICP-AES after Microwave Digestion

LIU Songtao, ZHANG Jing, CHEN Chuanmin, JIA Wenbo   

  1. School of Environmental Science and Engineering, North China Electric Power University, Baoding 071003, China
  • Received:2015-12-03 Online:2016-08-10 Published:2016-08-12

摘要: 测量变压器油中金属元素,必须进行油样预处理。为提高样品处理效率,建立了三段微波消解法。将HNO3-H2O2作为消解用酸,结合三段微波消解法,采用电感耦合等离子体发射光谱(微波消解-ICP-AES法),测定了油样中铜、铁元素的含量。实验结果表明,两元素含量测定值的相对标准偏差均小于2%,且加标回收率为97%~101.2%,与DL/T 263—2012《变压器油中金属元素的测定方法》进行对比,经t检验(α=0.05),无显著性差异。微波消解-ICP-AES法操作简便、检测快速、测量精度高,将其用于变压器油中金属元素的检测具有重要意义。

关键词: 变压器油, 金属元素检测, 三段微波消解, 等离子体光谱

Abstract: The pretreatment of transformer oil samples must be carried out before the process to determine the metal elements in transformer oil. In order to improve the efficiency of sample treatment, the three-step microwave digestion method is established. Using HNO3-H2O2 as the digestion acid and the method of ICP-AES in combination with the three-step microwave digestion, the Fe and Cu contents in the oil sample are measured. The results show that the RSDs of the two element contents are kept below 2% with the recoveries of standard addition between 98.4% and 101.2%. The analytical results obtained by the three-step microwave digestion method are compared with those by the China electric power industry standard(DL/T 263-2012 ). Verified by t-test at the confidence level of α=0.05, no significant difference is observed between the two methods. This method is simple, rapid and accurate, which is of great significance to detect the metal elements in transformer oil.

Key words: transformer oil, metal element determination, three-step microwave digestion, plasma spectrometry

中图分类号: