  • 摘要: 针对交流微电网高渗透率分布式电源接入及运行方式灵活的特性,鉴于传统配电网保护难以兼顾其可靠性与稳定性,提出一种基于负序/谐波融合判据的改进反时限过电流保护方案。该方案对微电网内部发生不对称故障下的负序电流特性和不同故障前后电流谐波畸变特性进行了研究,计算固定时窗内的负序电流积聚量和电流谐波畸变率,构建包含负序加速因子和谐波畸变加速因子的融合判据,以缩短反时限过电流保护的动作时间,并优化多级保护配合。基于PSCAD的仿真结果验证了改进反时限过电流保护方案在微电网不同运行模式下和不同故障下的有效性和可靠性。

     

    Abstract: Addressing the characteristics of high penetration of distributed generation and flexible operation modes in AC microgrids, and considering that traditional distribution network protection struggles to meet the requirements for both reliability and stability, an improved inverse-time overcurrent protection scheme based on a negative-sequence/harmonic fusion criterion is proposed. This scheme investigates the negative-sequence current characteristics under asymmetric faults and the current harmonic distortion characteristics before and after various faults within the microgrid. By calculating the accumulation of negative-sequence current and the current harmonic distortion rate within a fixed time window, a fusion criterion incorporating both negative-sequence and harmonic distortion acceleration factors is constructed to reduce the operating time of the inverse-time overcurrent protection and optimize the coordination among multi-stage protections. PSCAD-based simulation results demonstrate the effectiveness and reliability of the proposed improved scheme under various operation modes and fault conditions of the microgrid.

     

/