中国电力 ›› 2019, Vol. 52 ›› Issue (1): 156-160.DOI: 10.11930/j.issn.1004-9649.201805181

• 节能与环保 • 上一篇    下一篇

燃气机组NOx监测系统现状及其改进措施

张承武, 宣添星, 刘志坦, 杨爱勇, 舒喜   

  1. 国电环境保护研究院有限公司, 江苏 南京 210031
  • 收稿日期:2018-05-28 出版日期:2019-01-05 发布日期:2019-01-14
  • 作者简介:张承武(1966-),男,高级工程师,从事电厂脱硫、脱硝和除尘环保装置热控专业工作,E-mail:13951700744@139.com

Current Situation and Improvement Measures of NOx Monitoring System for Gas Turbine Unit

ZHANG Chengwu, XUAN Tianxing, LIU Zhitan, YANG Aiyong, SHU Xi   

  1. National Environmental Protection Research Institute for Electric Power, Nanjing 210031, China
  • Received:2018-05-28 Online:2019-01-05 Published:2019-01-14

摘要: 随着燃气机组NOx浓度排放要求日趋严格,其监测系统运行工况发生变化,原有监测仪表已不适用。通过分析NOx监测技术及其适应性和烟气预处理技术及其适应性,对燃气机组NOx监测系统现状有了明确的认识。结合HJ 75—2017和HJ 76—2017标准,针对现有监测系统中存在量程大、低浓度测量精度差、未监测NO2等问题,提出了一系列改进措施,如优先采用化学发光法NOx测量技术,增加NO2监测装置,采用低量程高精度CEMS仪表及性能优越的预处理装置,落实防雷设施等,同时着重考虑配置氨逃逸、氧量和湿度等分析仪表,以满足控制和监测要求。研究结果也同样适用于普通火电机组。

关键词: 燃气机组, NOx排放浓度, NO2, 测量仪表量程, 排放标准

Abstract: With the increasingly strict requirements for the concentration of NOx emission from gas-fired units, the operating condition of the monitoring system has changed such that the original monitoring instruments becomes no longer applicable. By analyzing the NOx monitoring technology and the flue gas pretreatment technology as well as their adaptabilities, a clear understanding of the current situation of the NOx monitoring system for gas units is obtained. In compliance with HJ 75-2017 and HJ 76-2017 standard, regarding the issues in existing monitoring system such as large measurement range, poor measurement accuracy for low concentration and lack of NO2 monitoring functionality a series of improvement measures are put forward, e.g., giving priority to chemiluminescence method in NOx measuring technology, adding NO2 monitoring devices, using low range and high precision CEMS instrument and pretreatment device with superior performance, implementation of the lightning protection facilities, etc.. Meanwhile the installation of ammonia escape, oxygen and moisture analysis instrument is taken into account in order to meet the control and monitoring requirements. The results are also applicable to regular thermal power units.

Key words: gas generating set, NOx emission concentration, NO2, measuring instrument range, emission standards

中图分类号: