高级检索

基于频率相关差模波阻抗的海底电缆柔性直流线路行波方向保护方法

A travelling-wave directional protection method for submarine cable MMC-HVDC lines based on frequency-dependent differential-mode wave impedance

  • 摘要: 针对海底电缆柔性直流线路中波阻抗频率相关特性显著、传统行波方向判别方法难以兼顾前/后向行波准确分离与可靠方向识别的问题,提出一种基于频率相关差模波阻抗的行波方向保护方法。通过建立频率相关差模波阻抗模型并进行有理函数拟合,将前/后向行波的频域耦合关系转化为时域离散递推卷积,实现前/后向行波的快速分离;针对卷积映射中的幅值不一致问题,引入幅值一致性修正,提高特征量可比性;结合首波到达时刻门控与滑动窗能量累积,构建前/后向行波能量比方向判据。基于江苏如东海上风电场柔直工程仿真模型的多类故障及非故障暂态验证结果表明,所提方法在所测试工况内具有良好的可靠性与选择性,可为海底电缆柔性直流线路快速方向保护提供新的思路。

     

    Abstract: A travelling-wave directional protection method based on frequency-dependent differential-mode wave impedance is proposed for submarine cable MMC-HVDC lines. By establishing a frequency-dependent differential-mode wave impedance model and applying rational fitting, the forward/backward travelling-wave coupling relationship is transformed into a time-domain discrete recursive convolution form for fast wave decomposition. An amplitude consistency correction is introduced to improve feature comparability, and an energy-ratio-based directional criterion is constructed using initial wave arrival-time gating and sliding-window energy accumulation. Tests on the Rudong offshore wind power MMC-HVDC simulation model under various fault and non-fault transient conditions verify that the proposed method provides good reliability and selectivity for fast directional protection of submarine cable MMC-HVDC lines.

     

/

返回文章
返回