1 葛耀中. 新型继电保护和故障测距的原理与技术[M]. 2版. 西安:西安交通大学出版社,2007. [2] 李幼仪,董新洲,孙元章. 基于电流行波的输电线横差保护[J]. 中国电机工程学报,2002,22(11):7-11. LI You-yi, DONG Xin-zhou, SUN Yuan-zhang. Current-travelling- wave-basde protection of double-circuit transmission line[J].Proceedings of the CSEE, 2002, 22(11): 7-11. [3] 任达勇,王志滨,冯鸫,等. 基于行波原理的直流输电线路过渡电阻在线测量[J]. 中国电力,2010,43(3):23-26. REN Da-yong, WANG Zhi-bin, FENG Dong, et al . On-line measuring of fault resistance on HVDC transmission lines based on traveling wave principle [J]. Electric Power, 2010, 43(3): 23-26. [4] 康小宁,索南加乐. 基于参数识别的单端电气量频域法故障测距原理[J]. 中国电机工程学报,2005,25(2):25-30. KANG Xiao-ning, SONGNAN Jia-le. Frequency domain method of fault location based on parameter identification-using one terminal data [J]. Proceedings of the CSEE, 2005, 25(2): 25-30. [5] 陈晓娟,王丽,隋吉生,等. 一种配电网单相接地故障定位新方法[J]. 中国电力,2011,44(10):33-36. CHEN Xiao-juan, WANG Li, SUI Ji-sheng, et al . A new method of single-phase ground fault location in 10 kV distribution network[J]. Electric Power, 2011, 44(10): 33-36. [6] 黄悦华,王永辉. 暂态初始行波相位比较法接地故障选线研究[J]. 中国电力,2008,41(4):11-14. HUANG Yue-hua, WANG Yong-hui. A study of earth fault detection by comparing phase of initial transient traveling wave [J]. Electric Power, 2008, 41(4): 11-14. [7] 李一峰,陈平. 一种反应输电线路故障行波的测距方法[J]. 中国电力,2007,40(12):68-71. LI Yi-feng, CHEN Ping. A novel method of fault location for transmission lines using traveling waves [J]. Electric Power, 2007, 40(12): 68-71. [8] 秦小安,曾祥君,万磊,等. 基于网络的电网故障行波保护方法[J]. 中国电力,2009,42(8):15-18. QIN Xiao-an, ZENG Xiang-jun, WAN Lei, et al . Traveling wave protection method of power grid fault based on network [J].Electric Power, 2009, 42(8): 15-18. [9] 陈铮,董新洲,罗承沐. 单端工频电气量故障测距算法的鲁棒性[J]. 清华大学学报:自然科学版, 2003,43(3):310-313. CHEN Zheng, DONG Xin-zhou, LUO Cheng-mu. Robustness of one-term inal fault location algorithms based on power frequency quality [J]. Tsinghua University: Sci & Tech, 2003, 43(3): 310-313. [10] 吴萍,张尧. 基于单端电气量的故障测距算法[J]. 电力系统及其自动化学报,2003,15(4):5-7,31. WU Ping, ZHANG Yao. Location using one-term inal data for transmission line [J]. Proceedings of the EPSA, 2003, 15(4): 5-7, 31. [11] 徐青山,陈锦根,唐国庆. 考虑母线分布电容影响的单端行波测距法[J]. 电力系统自动化,2007,31(2):70-73. XU Qing-shan, CHEN Jin-gen, TANG Guo-qing. Single ended fault location approach considering bus distributed capacitance effect[J]. Automation of Electric Power Systems, 2007, 31(2): 70-73. [12] 钟小垒,李京. 基于行波耦合原理的高压直流输电系统接地极引线故障测距[J]. 山东理工大学学报,2012,26(3):54-59. ZHONG Xiao-lei, LI Jing. Fault location of grounded electrode lead in HVDC system based on the principle of coupled travelling wave [J]. Journal of Shandong University of Technology,2012, 26(3): 54-59. [13] 张德丰. Matlab小波分析[M]. 北京:机械工业出版社,2009. [14] 清华大学. HPR-7000高精度故障录波与测距装置使用说明[S]. 北京:清华大学,2010. [15] 王志华.超高压输电线路故障行波定位及高压变频技术研究[D]. 武汉:华中科技大学,2004. |